-40%

TANDEM MATCH 2kW SWR POWER meter protection RX-TX ANT A-B LDMOS MOSFET BLF188XR

$ 24.81

Availability: 41 in stock
  • Brand: Danuby
  • Compatible Brand: Universal
  • Type: Power/SWR Meter
  • Condition: New
  • All returns accepted: ReturnsNotAccepted
  • MPN: Does Not Apply
  • Model: OUT UNIT

    Description

    Board
    OUT UNIT
    designed for high power amplifiers
    (up to
    2kW
    )
    in HF band 1-50MHz.
    This can be very useful as the core of a power meter, or as a component in an amplifier system.
    Applies a variant of the well-published "Tandem Match", it can measure forward and reflected power at the same time, without having to throw a switch to do it.
    It provides the ability to measure forward and reflected power levels; this is especially important in detecting high reflected power conditions, such as a damaged antenna, or when we forget to connect the coax to the output of an amplifier, etc
    .
    The signal of FOR (see scheme -
    VD4 - U1:3) is used for measurement of power.
    The signal of REF
    (see scheme -
    VD5 - U1:2)
    is used for measurement and for system of protection against high REF value.
    Components U1:4, VT3, VT5, VT6 create "
    G_STOP", "
    + _ STOP"
    signals for protection of the amplifier. Keys of signals of protection of G_STOP and + _ STOP with "latch" (VT4). I.e. signals G_STOP, +_STOP disappear only with the return of the amplifier in the RX mode.
    Board
    OUT Unit
    includes:
    1. Directional coupler TR1,
    2. Amplifiers U1:2, U1:3 for SWR-POWER meter,
    3. Protection - comparator U1:4,
    4. Keys switching - VT3, VT4, VT5, VT6,
    5. Relays RX-TX; ANT A - ANT B - K1,
    K2
    . VT1, VT2 control the operation of the relays,
    6. U1:1, VD10, VD12 form a voltage of negative polarity to ALC protect the transceiver,
    7. VD6, R37 - ALC voltage to the transceiver (
    the voltage of the negative polarity)
    ,
    8. VD1, RU1 - protection of static voltage from the antenna.
    The size of the core TR1 10x20x15mm allows you to measure the power of at least
    2000W
    .
    At the same time resistance of loading has to be 50 Ohms.
    To manage protections of amplifier OUT Unit gives several options signals:
    G_STOP -
    Open drain up to 100mA, U<25V
    +_STOP - output +12V up to 100mA
    ALC – output to -10V
    If SWR exceeds value (which you will choose as resistors R21, R29) - VT3 will open.
    VT3 will stay open through VT4, while there is a voltage of +12V_TX.
    When switching to RX mode - protect turns off.
    A-B - switching the antenna A - antenna B. To switch to apply a voltage of +5-12V.
    +12V_TX - Voltage +12V TX from the amplifier, which switches the amplifier from RX-mode to TX mode.
    FOR – measurement of power
    REF – measurement of SWR
    Size PCB 90x71mm
    The graph shows the dependence of the output voltage on the transmitted power.
    You can build a similar chart yourself online - link to the resource - https://www.kontrolnaya-rabota.ru/s/grafik/tochka/
    Enter the table -
    0;0
    0.82;10
    1.35;20
    1.80;30
    2.12;40
    2.42;50
    2.69;60
    2.96;70
    3.24;80
    3.43;90
    3.56;100